1. TCP/IP and RS485 communication to remote control the
lock
2. RFID Mifare technology
3. Network power supply
4. Real-time adjust the time
BW823 series network door lock
BW823 series networked door lock is a component part of BW823
series network lock System. This system includes:
Management computer, management software, card reader, RF card,
RF card door lock, data server PC, Network line concentrator,
lock controller, and smart ID identification switch, etc.
Characteristic
1. TCP/IP and the RS485 communications method: Management
computer connects to the controller through TCP/IP protocol,
and the controller to the electronic lock via RS485
communications method
2. Real-time communicated with the management computer, any
abnormal condition (unlocking, break in, etc) happened, the
management company can receive the warning info immediately,
and the hotel securities custody clerk or staffs can take the
quickest action.
3. Most work can been operated by the management software, for
example: Authorize or disable the card, inquiry the switch
status and the unlocking record, remote control to unlock or
locking the doors, etc. Which is quite simple and easy.
4. Once the fault or communication outage happened, the
management computer will receive the warning information
message immediately, so that the hotel engineer department can
dispatch the staff to check and settle the problems in time. It
helps the hotel find the problem before guests use/find it.
5. The door lock can been supply power by network, no need to
change the lock batteries
6. Greatly reduce workload, decrease the staffs and cost.
7. The management computer automatic calibrates the lock clock
every 5 minutes, which not only ensures the accuracy, but also
increases the stability of the lock system.
8. The management computer can initialize /setup the door locks
directly
9. There ways to unlock the door: By remote-control, by RF card
and when emergency occurs, by mechanical key or by the
management computer.
11. It is compatible with the FAS (fire alarm system), safety
subsystem. The related areas will start automatically when an
emergency occurs.
12. Distinctive quadrate tongue can effectively prevent
mechanical collision.
Technical item
|
Parameter Description
|
Inductive Distance
|
≥ 20mm
|
Power Supply
|
DC 6V; low-voltage alarm 4.8V.
|
Service Durability
|
more than 100000 times
|
Life Time
|
10 years
|
Door Thickness
|
38~55mm
|
Weight
|
3.7KG
|
Environment Requirement
|
Temperature: -45~80 degrees
|
Humidity
|
≤ 95%
|
Effective Time of unlocking the lock
|
5 seconds
|
Quiescent Current
|
< 30 uA
|