Quick Details (View All)

TypeEnergy Meter CertificationRoHS, ISO, CE
CustomizedCustomized CommunicationRS-485/Modbus-RTU Protocol
Compound Rate of Electrical Energy8 Multi-Rated Periods, 4 Rates Can Be Set Real-Time ClockYear, Month, Day, Minute, Second
Weight0.5kg Transport PackageCarton
Specification96 X 96X 102mm TrademarkKINGNEN
OriginChina Production Capacity2000/Month

Product Details

Product Description

Company Info.

  • Overview
  • Product Description
  • Product Parameters
  • Dimensions & Mounting
  • Application
Overview

Product Description


PMC96S meter is a multi-functional power monitoring meter, it combines function of collecting data and control, and it can replace many kind of meters, relays, transformers and others components. PMC96S can be installed in different positions of electricity distribution system.

Product Description

Host features

Instantaneous true RMS value

Current each single phase and conjunction, average

Phase voltage/line voltage each single phase and conjunction, average

Active, reactive, apparent power each phase and the sum of three phases

Power factor each phase and the sum of three phases

Frequency 45~65Hz

Maximum/minimum value

Max/min rms current

Max/min rms phase voltage

Max/min total active, reactive, apparent power

Max/min total power factor

Max/min frequency

Max/min THD I and THD U

Demand and peak demand value

Current per phase current value/peak/month end peak

Total active, total reactive, total apparent power current value/peak/month end peak

Energy

Input/output/total active energy 1 pulse output

Input/output/total reactive energy 1 pulse output

Apparent electrical energy

Monthly electrical energy

Compound rate of electrical energy

8 multi-rated periods, 4 rates can be set

Power quality

Total Harmonic Distortion Rate (THD) current and voltage

1st-31st harmonic analysis current and voltage

Voltage crest factor CF and current K coefficient

Event logging

100 SOE event records

Alarm system

8 configurable limit alarm channels

4 configurable logical alarm channels

Communication

RS-485 /MODBUS-RTU Protocol

Display

STN LCD display

Real-time clock

Year, month, day, minute, second

Other

Program online upgrade supported

Optional features

Digital Input (DI) module (optional)

2 switching inputs

Digital Output (DO) module (optional)

2 relay outputs, which can be set by local overrun alarm or controlled remotely

Analog Input (AI)/Output (AO) module (optional)

2 channels. 4-20mA DC analog input, 0-5V DC analog input, 4-20mA DC analog output optional.

Product Parameters

Electrical characteristics

System

Three-phase three-wire AC system, three-phase four-wire AC system;

Sample rate

128 samples per cycle

Data refresh rate

1s

Measurement accuracy

Current

±0.2%FS

Voltage

±0.2%FS

Power

0.5S

Frequency

±0.001Hz

Active energy

0.5S

Reactive energy

1.0S

DC input (AI)

0.5% FS

DC output (AO)

0.5% FS

Voltage input

Measure voltage

3*220/380V (Direct input)

3*57.7/100V (PT secondary)

Overload

1.2x/continuous

Input impedance

300KΩ per phase

Current input

Measure current

5A (CT secondary) or 1A (CT secondary)

Overload

1.2x/continuous

Input impedance

<0.1Ω

Digital input

Operating voltage

15 VDC

Input impedance

12 KΩ

Isolation voltage

2 KV

Digital output

Node type

Mechanical contacts

Node capacity

220 VAC/5A,30 VDC/5A

4~20mA DC input measurement

Measure current

4~20mA

Allowed overload capacity

1.2x/continuous

Input impedance

10 Ω

Isolation voltage

2 KV

0~5 V DC input measurement

Measure voltage

0~5 V

Allowed overload capacity

1.2x/continuous

Input impedance

12.5 KΩ

Isolation voltage

2 KV

4~20mA DC output

Open-circuit voltage

15 VDC

Load capacity

≤600 Ω

Isolation voltage

2 KV

Working power supply

AC

100~240 VAC/45~65Hz

DC

100~375 VDC

power consumption

< 3 W

Mechanical characteristic

Weight

0.5 kg

IP protection rating

Instrument panel IP52, instrument body IP30

Size

host

96 *96 * 72 mm

Host + module

96 * 96 * 120 mm

Operating temperature

display

-20~70°C

Instrument

-25~70°C

Storage temperature

instrument + display

-40~85°C

Humidity

5% ~ 90%RH, non-condensing

Electromagnetic compatibility

Electrostatic discharge

IEC 61000-4-2, Level 4

Fast transient

IEC 61000-4-4, Level 4

Surges

IEC 61000-4-5, Level 3

Magnetic fields

IEC 61000-4-8, Level 3

Electrical insulation

Insulation resistance

GB/T13729,>50 MΩ

AC voltage

GB/T13729, AC 3KV 50Hz /1min

Impulse voltage

GB/T13729,5KV,1.2/50us

Dimensions & Mounting

The size of the instrument and cutout is shown below (Unit: mm).
Then Embed the meter into the 90mm*90mm cutout slot and screw on the fixing buckle, as shown in the picture followed.

Application

The instrument, as shown in the figure below, is in charge of measuring and collecting power data for each loop and is located in the collection layer. Simultaneously, the instrument equipped with a DI/DO and an AO module may achieve switch status monitoring, relay output, and a transmitter, all of which can be adjusted to your specific requirements.

chat with us
Register Your Company