Connect Drain Line (Y port) to oil tank
independently so as to obtain stable pressure
setting. At the same time, the solenoid
controlled pilot operated directional valve to be
used in combination with this valve must be of
internal drain type (with T)
To make pressure adjustment, loosen
the lock nut and turn the pressure adjustment
screw clockwise or anticlockwise. For an
increase of pressure, turn the screw clockwise.
Be sure to re-tighten the lock nut firmly after
making adjustment to the
pressure