Evaporative Air Cooler Voltage: 220-240V~50/60Hz
Rated cooling power:80W
Tank Capacity:20L
N/G Weight:5KGS/6KGS
Maximum Air Volume:3500m³/h
Control Mode:Switch button
Air level:Three levels
Air mode:Nature/Sleep/Normal
Swing mode:Left & Right auto/Up & Down/manual
Product dimension:430*315*795mm
Packing Dimension:485*360*780mm
486PCS/40HQ
FAQ
Q1: How does the air cooler
do not have cold air?
The possible causes may include:The tank is short of water or
the ice crystals have melted.
The fan filter screen is blocked and needs to be cleaned.
The cooling components of the fan such as the wet curtain
need to be replaced.
Check the tank water level, clean the filter screen, and
consider replacing the refrigeration components.
Q2: When the cooling fan is noise, how to solve
it?
Noise may be caused by the following reasons:Fan blades are
unbalanced or damaged.
Motor bearing wear.
The cooling fan placement is not stable.Check the fan blades
and replace the motor bearings to ensure that the cooling fan
is placed on a stable and flat surface.
Q3: The refrigeration effect of the cooling fan is not
good, how to do it?
The following possible reasons are provided:The environmental
humidity is too high, which affects the refrigeration
effect.
Refrigeration components such as wet curtain aging.
The wind speed of the fan setting is too low.
Try using it when the humidity is low, replace the cooling
components, or adjust the wind speed setting.
Q4: Cold fan smell out, how to solve it?.
The odor may be due to:Not clean for a long time, leading to
bacterial breeding.
The water quality in the tank is poor or not replaced for a
long time.
Clean the cooling fans regularly, replace the water in the
water tank, and use pure water or add an appropriate amount
of disinfectant.
Q5: What is the cold fan not rotating?.
The possible causes include:Power problem, power not
connected or power unstable.
Motor failure.
Remote control or control panel failure.
Check the power connection and verify that the motor and
control panel are properly.
Q6: What if the remote control of the cooling fan cannot
be controlled?
The following possible reasons are provided:
Remote control battery is exhausted.
The signal between the remote control and the cold fan is
blocked.
The remote control itself fails.
Replace the remote control battery, check for an object
blocking signal, or try to operate directly on the cooling
fan.
Q7: What happens if the cooling fan leaks?
The possible causes include:Water tank leakage.
Drain pipe is blocked or improperly located.
Refrigeration components such as wet curtain
installation.
Check the water tank and drain pipe to ensure that the
cooling components are installed correctly.
Q8: How to clean the water tank of cold fans?
The steps of cleaning the water tank include:
Disgle the power and pour the water in the water tank.
Use mild cleaner and water to clean the water tank.
Rinse it with water and reinstall it after drying.
Q9: Does the cold fan need to be maintained
regularly?
Yes, in order to ensure the performance and service life of
cold fans,
Suggestion: Clean the filter every two weeks.
Check the refrigeration parts every month like a wet
curtain.
Maintain comprehensive maintenance every six months or a
year.