2000A 3p 4p Acb Dw45 Intelligent Drawer Type Air Circuit Breaker

Quantity 5 - 9 10 - 19 20+ - 20+
Price US $800.00 US $750.00 US $700.00

Quick Details (View All)

Poles Number1 TypeCircuit Breaker
FunctionConventional Circuit Breaker CertificationVDE, ISO9001:2008
Rated Frequency (Hz)50 Number of Pole3
Product NameGw1 Rated Current1250A
ProtectionLSI ApplicationElectric Power Transmission
MOQ1 Piece Rated Voltage400V
TrademarkGGAOE OriginZhejiang, China
HS Code7201500010 Production Capacity100000 Piece/Pieces Per Month

Product Details

Product Description

Company Info.

  • Overview
  • Products Description
  • Felds of Application
  • Company Profile
  • Certifications
  • Delivery
  • FAQ
Overview

Product Description

Products Description
overview
WCW1 series intelligent univeral circuit breaker (circuit breaker for short) applies at distribution network of AC 50Hz, rated voltage upto 600V( 690V), rated current 200A to 6300A, to distribute power and protect line and power supply equipments from fault demage of overload, under voltage, short circuit, single phase grounding. The circuit breaker has function of intelligent Protection with accurate selection to increase power supply reliability ths to avoid unnecessary power cut. It has open
communication interface to make "Four-remote type Control" to fulfill requirements of control center and automatic system. The circuit breakers impulse withstand voltage is 8000V when at altitude 2000 meter (Clarity according to standards of different altitude not over 12000V.)
odel
GW3-1600
GW3-2000
GW3-2500
GW3-3200
GW3-4000
GW3-6300
GW3-7400
Number of poles
3p, 4p
3p, 4p
3p, 4p
3p, 4p
3p, 4p
3p, 4p
3p, 4p
Rated current In (A)
200, 400, 630, 800, 1000, 1250, 1600
630, 800, 1000, 1250, 1600, 2000
1600, 2000, 2500
2000, 2500, 2900, 3200
2900, 3200, 3600, 4000
4000, 5000, 5500, 6300
4000, 5000, 6300, 3900, 7400
Rated voltage (V)
AC400, 690V, 50Hz
Rated Insulation voltage
AC1000V 50Hz
Rated impulse withstand voltage Uimp (KV)
12
Power frequency withstand voltage U (V)
AC3500V 1min 50Hz
Rated ultimate short-circuit breaking capacity Icu (KA)
400V
65
80
85
100
100
135
150
690V
42
65
65
75
85
100
100
Rated service short-circuit breaking capacity lcs (KA)
400V
55
65
85
80
100
135
150
690V
42
50
65
65
85
100
100
Rated short time withstand current lcw (KA)
400V
55
65
85
80
100
135
150
690V
42
50
65
65
85
100
100
Rated short-circuit making capacity lcm (KA)
400V
143
187
187
220
220
297
330
690V
88.2
143
143
187
187
220
220
Complete break-time
≤30
Closing time
≤50
Utilization category
B
Isolation function
Circuit breaker suitable for isolation
Intelligent controller model
L/M/H
Performance
Electrical life (times)
400V
7000
8500
8500
5000
5000
3000
2000
690V
5000
4000
4000
3000
3000
3000
1500
Mechanical life (times)
16000
13000
13000
11000
11000
7000
7000
Outline dimension (mm)
Withdrawable type
3P
354×282×357
438×375×456
438×375×475
438×435×471
438×435×490
438×799×490
438×894×530
4P
354×352×357
438×470×456
438×470×475
438×550×471
438×550×490
438×894×490
438×894×530
Dixed type
3P
330×261×254
398×362×350
398×362×350
398×422×365
398×422×373.5
398×767×373.5
398×882×373.5
4P
330×331×254
398×457×350
398×457×350
398×537×365
398×537×373.5
398×882×373.5
398×882×373.5
Standard
IEC60947-2
Certificate
CCC, CE
Operating ambient temperature
-25ºC ··+60ºC
Storage temperature
-40ºC ··+70ºC
Correction factor for temperature:
Ambient temperature
+40ºC
+45ºC
+50ºC
+55ºC
+60ºC
Allowable persistent operating current
1600A
1ln
0.99ln
0.96ln
0.90ln
0.87ln
2000A
1ln
0.95ln
0.9ln
0.85ln
0.81ln
2500A
1ln
0.95ln
0.9ln
0.85ln
0.81ln
3200A
1ln
0.92ln
0.86ln
0.80l
0.74ln
4000A
1ln
0.92ln
0.86ln
0.80ln
0.74ln
6300A
1ln
0.94ln
0.88ln
0.82ln
0.76ln
7400A
1ln
0.94ln
0.88ln
0.82ln
0.76ln
Correction factor for altitude:
Altitude
2000
3000
4000
5000
Power frequency withstand voltage U (V)
3500
3150
2500
2000
Correction factor for operating current
1
0.93
0.88
0.82
Correction factor for short-circuit breaking capacity
1
0.83
0.71
0.63

Ordering Instructions:

The following technical information should be provided when placing an order: Main wiring scheme number, purpose and single line system diagram, rated voltage and rated current rated short-circuit breaking current/distribution room layout plan and arrangement and configuration diagram of switchgear;
Requirements for control measurement and protection functions of switchgear, as well as requirements and schematic diagrams for other interlocking and automatic devices;
The models specifications and quantities of the main electrical components inside the switchgear;
When the switchgear is used in special environmental conditions; detailed instructions should be provided when placing an order;
Felds of Application
Company Profile
Certifications
Delivery
FAQ
Q:whats your major products?
A: oil immersed transformer, dry type transformer, Transformer Substation, High and Low Voltage Switchgear

Q: Can your product be customized?
A: Considering differences in voltage, frequency and other special transformer product in different countries and regions, our product can be customized according to your requirements.

Q: When can I get the price?
A:Usually we quote within 24 hours after we get your inquiry.

Q: What about lead or shipping time?
A: The lead time depends on the quantity you ordered, generally within 15 days upon receipt of advance payment.

Q: What is the price of shipping?
A: Depending upon the port of delivery, prices varies.

Q: Do you offer guarantee for the products?
A: Yes. We offer at least one years guarantee for all of our transformers.

Q: Your Advantage?
A: 15 years experience, Advanced production equipment, Stable quality, Fast delivery, Professional & good & Prompt service. Also some free parts can be provided for you.
chat with us
Register Your Company